general data
|
| measuring distance Sd |
100...500 mm or
200...1000 mm |
| beam type |
point or line |
| sensing element |
photoelectric array |
| adjustment |
no |
|
power on indication
|
LED green |
| soiled lens indicator |
LED red / LED red blinking |
|
| light source |
pulsed red laser diode |
| wave length |
675 nm |
| laser class |
2 |
|
|
|
electrical data - current
output
|
| voltage supply range +Vs |
12 ... 28 VDC |
| current consumption max. |
120 mA |
| output circuit |
analog |
| output signal |
4 ... 20 mA |
|
| load resistance |
< (+Vs - 6 V) / 0,02 A |
| short circuit protection |
yes |
| reverse polarity protection |
yes, Vs to GND |
|
|
|
electrical data - voltage
output
|
| voltage supply range +Vs |
12 ... 28 VDC |
| current consumption max. |
120 mA |
| output circuit |
analog |
| output signal |
0 ... 10 VDC |
|
| load resistance |
> 100 kOhm |
| short circuit protection |
yes |
| reverse polarity protection |
yes, Vs to GND |
|
|
|
mechanical data
|
| width / diameter |
20,6 mm |
| height / length |
65 mm |
| depth |
50 mm |
|
| housing material |
die-cast
zinc |
| front (optics) |
glass |
| connection types |
connector
M12, 5 pin, rotatable |
|
|
|
ambient conditions
|
| operating temperature |
0 ... +50 °C |
|
|
|
|
|
|