Home > Manufacturers > K - O > LEESON > AC Motors > 3-Phase > Washguard Duty >

132207-00 - Leeson 132207.00 5HP 3515RPM.184TC.TEFC.208-230 / 460V.3PH.60 / 50HZ.CONT.40C.1.25SF.RIGID C.C184T34WK11A .WASHGUARD-ALL STAINLESS

132207-00 - Leeson
132207.00
 
Price: $2,763.15
Returnable: NOT RETURNABLE
Manufacturer SKU: 132207.00
Manufacturer ID: C184T34WK11A


Availability: Usually Ships in 3 to 5 Days
Part Number: 132207-00
Qty:

Description Documents & Downloads
 
Please note that this product does NOT qualify for free shipping and may require truck freight.
This Product Ships PREPAID and ADD Only!


LEESON 132207.00
Engineering Data
Volts 208-230 Volts 460 Volts 190/380 
F.L. Amps 13-12 F.L. Amps 6 F.L. Amps 14/7
S. F Amps 15-14 S. F Amps 7 S. F Amps 16/8

RPM 3600 Hertz 60/50    
HP 5 Duty CONTINUOUS TYPE TF
KW 3.70        
Frame 184TC Serv. Factor 1.25 Phase 3
Max Amb 40 Design B Code K
Insul Class F Protection NOT Therm.Prot.
Eff 100% 88.5 Eff 75% PF 89
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6207
CC Number NONE CE Yes Bearing PE 6207
Load Type Inverter Type Speed Range NONE

Motor Wt. 103 LB Enclosure TEFC Lubrication POLYREX EM
Nameplate 081119 Mounting RIGID Rotation REV
Assembly 180-049 Shaft Dia. 1 1/8 IN Ext. Diag. 005010.01
Cust Part No Outline 035437-950 Ext. Diag2
Packaging B Winding T82103
Carton Label Leeson Stainless Washguard     GROUP:
Iris Paint NO PAINT Test Card 02

Form Factor   RMS Amps   Const Torque Speed Range  
Torque   Peak      
AB Code   Peak@DegC      
Resistance          
Connection          

Rework Status   Rework TYPE      

Hazardous Loc NONE  Brake Motors  
Explosion Proof   Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
        Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK?) 0  
Torque 7.5(Full Load) 26(Break Down) 15.5(Pull Up) 16(Locked Rotor)
CURRENT (amps) 6(Full Load) 30(Break Down) 47(Pull Up) 47(Locked Rotor)
Efficiency (%) 0(Full Load) 89.1(75% Load) 87.9(50% Load) 81.9(25% Load)
PowerFactor 0(Full Load) 87.5(75% Load) 81.1(50% Load) 62.9(25% Load)
Load Curve Data @60/50 Hz, 460 Volts, 5 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 1.7 0.2 3600 0.0 0.0 14.8 0.0 -
0.25 2.3 1.1 3576 1.8 81.9 62.9 0.0 -
0.5 3.3 2.1 3551 3.7 87.9 81.1 0.0 -
0.75 4.5 3.1 3526 5.6 89.1 87.5 0.0 -
1.0 6.0 4.2 3495 7.5 88.5 89.5 55.0 -
1.15 6.8 4.9 3477 8.7 88.3 90.5 75.0 -
1.25 7.4 5.3 3463 9.5 87.6 90.8 85.0 -
SOURCE: CALCULATED GROUP: 3