Walker Industrial: Home > Manufacturers > P - S > SSAC > Timers & Flashers > Tower & Obstruction Lighting Controls > FS & FA Series

FS & FA Series
Sort By:
1
FA155 - SSAC FA155 - SSAC Aux Module 120VAC 2500W NC 2x2 use with Fs155 30x

Aux Module 120VAC 2500W NC 2x2 use with Fs155 30x (SSAC FA155)

Usually Ships in 3 to 5 Days
Price: $166.94
FA155-2 - SSAC FA155-2 - SSAC Aux Module 120VAC 2500W NO 2x2 use with Fs155 30x

Aux Module 120VAC 2500W NO 2x2 use with Fs155 30x (SSAC FA155-2)

Usually Ships in 3 to 5 Days
Price: $166.94
FA165 - SSAC FA165 - SSAC Aux Module 230VAC 5000W NC 2x2 use with Fs155 30x

Aux Module 230VAC 5000W NC 2x2 use with Fs155 30x (SSAC FA165)

Usually Ships in 3 to 5 Days
Price: $166.94
FA165-2 - SSAC FA165-2 - SSAC Aux Module 230VAC 5000W NO 2x2 use with Fs155 30x

Aux Module 230VAC 5000W NO 2x2 use with Fs155 30x (SSAC FA165-2)

Usually Ships in 3 to 5 Days
Price: $166.94
FS155-30RF - SSAC FS155-30RF - SSAC Beacon Flasher 120VAC 2500W for High-RF Towers

Beacon Flasher 120VAC 2500W for High-RF Towers (SSAC FS155-30RF)

Usually Ships in 3 to 5 Days
Price: $164.41
FS155-30T - SSAC FS155-30T - SSAC Beacon Flasher 120VAC 2500W for Non-RF Locations

Beacon Flasher 120VAC 2500W for Non-RF Locations (SSAC FS155-30T)

Usually Ships in 3 to 5 Days
Price: $163.55
FS165-30T - SSAC FS165-30T - SSAC Beacon Flasher 230VAC 5000W for Non-RF Locations

Beacon Flasher 230VAC 5000W for Non-RF Locations (SSAC FS165-30T)

Usually Ships in 3 to 5 Days
Price: $164.41
   
 
1
FS & FA Series

B-KON Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and fail-safe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations; including AM hot towers.

Operation
FS Series - Flasher (OFF First)
FA Series - Flashers & Aux. Modules
Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.

Features:

  • Zero voltage switching - up to 10 times longer lamp life
  • No RFI caused by contacts closing
  • High inrush capability - up to 200A
  • RF model for AM hot towers & other high RF installations
  • Auxiliary units for synchronous flashing or constant line loading

Auxiliary Products:

  • Quick connect to screw adaptor: P/N: P1015-18
  • Female quick connect:
    • P/N: P1015-13 (AWG 10/12)
    • P/N: P1015-64 (AWG 14/16)
    • P/N: P1015-14 (AWG 18/22)