Walker Industrial: Home > Manufacturers > P - S > SSAC > Timers & Flashers > Timers > Dedicated > CT Series

CT Series
Sort By:
1
CT1S30 - SSAC CT1S30 - SSAC Timer HVAC 24VAC 0.75A Delay-on-Make 1s Delay-on-Break 30S

Timer HVAC 24VAC 0.75A Delay-on-Make 1s Delay-on-Break 30S (SSAC CT1S30)

Usually Ships in 3 to 5 Days
Price: $38.86
CT1S45 - SSAC CT1S45 - SSAC Timer HVAC 24VAC 0.75A Delay-on-Make 1s Delay-on-Break 45S

Timer HVAC 24VAC 0.75A Delay-on-Make 1s Delay-on-Break 45S (SSAC CT1S45)

Usually Ships in 3 to 5 Days
Price: $38.86
CT1S8 - SSAC CT1S8 - SSAC Timer HVAC 24VAC 0.75A Delay-on-Make 1s Delay-on-Break 8S

Timer HVAC 24VAC 0.75A Delay-on-Make 1s Delay-on-Break 8S (SSAC CT1S8)

Usually Ships in 3 to 5 Days
Price: $38.86
CT1S90 - SSAC CT1S90 - SSAC Timer HVAC 24VAC 0.75A Delay-on-Make 1s Delay-on-Break 90S

Timer HVAC 24VAC 0.75A Delay-on-Make 1s Delay-on-Break 90S (SSAC CT1S90)

Usually Ships in 3 to 5 Days
Price: $38.86
CT30S1 - SSAC CT30S1 - SSAC Timer HVAC 24VAC 0.75A Delay-on-Make 30s Delay-on-Break 1S

Timer HVAC 24VAC 0.75A Delay-on-Make 30s Delay-on-Break 1S (SSAC CT30S1)

Usually Ships in 3 to 5 Days
Price: $38.86
CT45S45 - SSAC CT45S45 - SSAC Timer HVAC 24VAC 0.75A Delay-on-Make 45s Delay-on-Break 45S

Timer HVAC 24VAC 0.75A Delay-on-Make 45s Delay-on-Break 45S (SSAC CT45S45)

Usually Ships in 3 to 5 Days
Price: $38.86
CT5S300 - SSAC CT5S300 - SSAC Timer HVAC 24VAC 0.75A Delay-on-Make 5s Delay-on-Break 300S

Timer HVAC 24VAC 0.75A Delay-on-Make 5s Delay-on-Break 300S (SSAC CT5S300)

Usually Ships in 3 to 5 Days
Price: $38.86
   
 
1
CT Series

The CT Series combines a delay-on-make and delay-on-break time delay into one unit and may be used to control fan delays in heating and/or cooling equipment. The CT includes bypass circuitry to allow it to operate with cooling anticipators ≥ 3000 ohms. It is designed to operate in 24VAC control circuits. Several CT modules may be combined to provide sequencing on of any number of loads and sequencing off of the same loads, such as electric heating elements.

Operation (Delay-on-Make/Delay-on-Break):
Forced Air Heating or Air Conditioning (as shown): When the thermostat closes, the compressor relay is immediately energized. At the end of a fixed delay-on-make delay (T1), the fan relay is energized. When the thermostat opens, the compressor relay is de-energized and the delay-on-break delay is initiated. On completion of the fixed delay-on- break delay (T2) the fan relay is de-energized. If the thermostat is reclosed during the delay-on-break delay, the delay-on-break delay is reset and the fan relay remains energized. If the thermostat is closed when input voltage is applied, the delay-on-make delay (T1) begins as normal.
Reset: Removing input voltage resets the output and time delays.

Features:

  • Delay-on-make and delay-on-break in one unit
  • Use for fan delays in heating or cooling equipment
  • Use for multiple load sequencing
  • 24VAC operation
  • Factory fixed delays from 1 - 600s in 1s increments

Auxiliary Products:

  • Female quick connect: P/N: P1015-64 (AWG 14/16)
  • Mounting bracket: P/N: P1023-6
  • Quick connect to screw adaptor: P/N: P1015-18
  • DIN rail: P/N: C103PM (Al)
  • DIN rail adaptor: P/N: P1023-20