Walker Industrial: Home > Manufacturers > P - S > SSAC > Timers & Flashers > Current Sensors & Monitors > ECS Series

ECS Series
Sort By:
1 2
ECS20BC - SSAC ECS20BC - SSAC Current Sensor 24VAC 0.5 5A 0.5 50s 1s Startup

Current Sensor 24VAC 0.5 5A 0.5 50s 1s Startup (SSAC ECS20BC)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS21BC - SSAC ECS21BC - SSAC Current Sensor 24VAC 2 20A 0.5 50s 1s Startup

Current Sensor 24VAC 2 20A 0.5 50s 1s Startup (SSAC ECS21BC)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS2HBC - SSAC ECS2HBC - SSAC Current Sensor 24VAC 5 50A 0.5 50s 1s Startup

Current Sensor 24VAC 5 50A 0.5 50s 1s Startup (SSAC ECS2HBC)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS30AC - SSAC ECS30AC - SSAC Current Sensor 24VDC 0.5 5A 0.15 7s 1s Startup

Current Sensor 24VDC 0.5 5A 0.15 7s 1s Startup (SSAC ECS30AC)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS31AC - SSAC ECS31AC - SSAC Current Sensor 24VDC 2 20A 0.15 7s 1s Startup

Current Sensor 24VDC 2 20A 0.15 7s 1s Startup (SSAC ECS31AC)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS40A - SSAC ECS40A - SSAC Current Sensor 120VAC 0.5 5A 0.15 7S

Current Sensor 120VAC 0.5 5A 0.15 7S (SSAC ECS40A)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS40AC - SSAC ECS40AC - SSAC Current Sensor 120VAC 0.5 5A 0.15 7s 1s Startup

Current Sensor 120VAC 0.5 5A 0.15 7s 1s Startup (SSAC ECS40AC)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS40BC - SSAC ECS40BC - SSAC Current Sensor 120VAC 0.5 5A 0.5 50s 1s Startup

Current Sensor 120VAC 0.5 5A 0.5 50s 1s Startup (SSAC ECS40BC)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS41A - SSAC ECS41A - SSAC Current Sensor 120VAC 2 20A 0.15 7S

Current Sensor 120VAC 2 20A 0.15 7S (SSAC ECS41A)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS41AC - SSAC ECS41AC - SSAC Current Sensor 120VAC 2 20A 0.15 7s 1s Startup

Current Sensor 120VAC 2 20A 0.15 7s 1s Startup (SSAC ECS41AC)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS41BC - SSAC ECS41BC - SSAC Current Sensor 120VAC 2 20A 0.5 50s 1s Startup

Current Sensor 120VAC 2 20A 0.5 50s 1s Startup (SSAC ECS41BC)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS41BD - SSAC ECS41BD - SSAC Current Sensor 120VAC 2 20A 0.5 50s 2s Startup

Current Sensor 120VAC 2 20A 0.5 50s 2s Startup (SSAC ECS41BD)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS41BH - SSAC ECS41BH - SSAC Current Sensor 120VAC 2 20A 0.5 50s 6s Startup

Current Sensor 120VAC 2 20A 0.5 50s 6s Startup (SSAC ECS41BH)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS4HBC - SSAC ECS4HBC - SSAC Current Sensor 120VAC 5 50A 0.5 50s 1s Startup

Current Sensor 120VAC 5 50A 0.5 50s 1s Startup (SSAC ECS4HBC)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS4HBH - SSAC ECS4HBH - SSAC Current Sensor 120VAC 5 50A 0.5 50s 6s Startup

Current Sensor 120VAC 5 50A 0.5 50s 6s Startup (SSAC ECS4HBH)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS60AH - SSAC ECS60AH - SSAC Current Sensor 230VAC 0.5 5A 0.15 7s 6s Startup

Current Sensor 230VAC 0.5 5A 0.15 7s 6s Startup (SSAC ECS60AH)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS60BC - SSAC ECS60BC - SSAC Current Sensor 230VAC 0.5 5A 0.5 50s 1s Startup

Current Sensor 230VAC 0.5 5A 0.5 50s 1s Startup (SSAC ECS60BC)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS61BC - SSAC ECS61BC - SSAC Current Sensor 230VAC 2 20A 0.5 50s 1s Startup

Current Sensor 230VAC 2 20A 0.5 50s 1s Startup (SSAC ECS61BC)

Usually Ships in 3 to 5 Days
Price: $123.18
ECS6HAH - SSAC ECS6HAH - SSAC Current Sensor 230VAC 5 50A 0.15 7s 6s Startup

Current Sensor 230VAC 5 50A 0.15 7s 6s Startup (SSAC ECS6HAH)

Usually Ships in 3 to 5 Days
Price: $123.18
ECSH30AC - SSAC ECSH30AC - SSAC Current Sensor Over 24VDC 0.5 5A 0.15 7s 1s Startup

Current Sensor Over 24VDC 0.5 5A 0.15 7s 1s Startup (SSAC ECSH30AC)

Usually Ships in 3 to 5 Days
Price: $126.65
ECSH40AC - SSAC ECSH40AC - SSAC Current Sensor Over 120VAC 0.5 5A 0.15 7s 1s Startup

Current Sensor Over 120VAC 0.5 5A 0.15 7s 1s Startup (SSAC ECSH40AC)

Usually Ships in 3 to 5 Days
Price: $126.65
ECSH40AD - SSAC ECSH40AD - SSAC Current Sensor Over 120VAC 0.5 5A 0.15 7s 2s Startup

Current Sensor Over 120VAC 0.5 5A 0.15 7s 2s Startup (SSAC ECSH40AD)

Usually Ships in 3 to 5 Days
Price: $126.65
ECSH41AC - SSAC ECSH41AC - SSAC Current Sensor Over 120VAC 2 20A 0.15 7s 1s Startup

Current Sensor Over 120VAC 2 20A 0.15 7s 1s Startup (SSAC ECSH41AC)

Usually Ships in 3 to 5 Days
Price: $126.65
ECSH41AD - SSAC ECSH41AD - SSAC Current Sensor Over 120VAC 2 20A 0.15 7s 2s Startup

Current Sensor Over 120VAC 2 20A 0.15 7s 2s Startup (SSAC ECSH41AD)

Usually Ships in 3 to 5 Days
Price: $126.65
ECSH41BC - SSAC ECSH41BC - SSAC Current Sensor Over 120VAC 2 20A 0.5 50s 1s Startup

Current Sensor Over 120VAC 2 20A 0.5 50s 1s Startup (SSAC ECSH41BC)

Usually Ships in 3 to 5 Days
Price: $126.65
ECSH41F.08D - SSAC ECSH41F.08D - SSAC Current Sensor Over 120VAC 2 20A 0.08s 2s Startup

Current Sensor Over 120VAC 2 20A 0.08s 2s Startup (SSAC ECSH41F.08D)

Usually Ships in 3 to 5 Days
Price: $126.65
ECSH4HAD - SSAC ECSH4HAD - SSAC Current Sensor Over 120VAC 5 50A 0.15 7s 2s Startup

Current Sensor Over 120VAC 5 50A 0.15 7s 2s Startup (SSAC ECSH4HAD)

Usually Ships in 3 to 5 Days
Price: $126.65
ECSH4HF.08D - SSAC ECSH4HF.08D - SSAC Current Sensor Over 120VAC 5 50A 0.08s 2s Startup

Current Sensor Over 120VAC 5 50A 0.08s 2s Startup (SSAC ECSH4HF.08D)

Usually Ships in 3 to 5 Days
Price: $126.65
ECSH61AD - SSAC ECSH61AD - SSAC Current Sensor Over 230VAC 2 20A 0.15 7s 2s Startup

Current Sensor Over 230VAC 2 20A 0.15 7s 2s Startup (SSAC ECSH61AD)

Usually Ships in 3 to 5 Days
Price: $126.65
ECSL31A - SSAC ECSL31A - SSAC Current Sensor Under 24VDC 2 20A 0.15 7S

Current Sensor Under 24VDC 2 20A 0.15 7S (SSAC ECSL31A)

Usually Ships in 3 to 5 Days
Price: $126.65
   
 
1 2
ECS Series

The ECS Series of single-phase AC current sensors is a universal, overcurrent or undercurrent sensing control. Its built-in toroidal sensor eliminates the inconvenience of installing a stand-alone current transformer. Includes onboard adjustments for current sensing mode, trip point, and trip delay. Detects over or undercurrent events like; locked rotor, loss of load, an open heater or lamp load, or proves an operation is taking place or has ended.

Operation:
Input voltage must be supplied at all times for proper operation. When a fault is sensed throughout the trip delay, the output relay is energized. When the current returns to the normal run condition or zero, the output and the delay are reset. If a fault is sensed and then corrected before the trip delay is completed, the relay will not energize and the trip delay is reset to zero.

Adjustment
Select the desired function, over or under current sensing. Set the trip point and trip delay to approximate settings. Apply power to the ECS and the monitored load. Turn adjustment and watch the LED. LED will light; turn slightly in opposite direction until LED is off. Adjustment can be done while connected to the control circuitry if the trip delay is set at maximum. To increase sensitivity, multiple turns may be made through the ECS's toroidal sensor. The trip point range is divided by the number of turns through the toroidal sensor to create a new range. When using an external CT, select a 2VA, 0-5A output CT rated for the current to be monitored. Select ECS adjustment range 0. Pass one secondary wire lead through the ECS toroid and connect the secondary leads together.

Features:

  • Toroidal through hole wiring
  • 0.5 - 50A trip points
  • Adjustable or factory fixed trip delays
  • Isolated, 10A, SPDT output contacts
  • 5% trip point hysteresis (dead band)

Auxiliary Products:

  • Female quick connect:
    • P/N: P1015-13 (AWG 10/12)
    • P/N: P1015-64 (AWG 14/16)
    • P/N: P1015-14 (AWG 18/22)