Walker Industrial: Home > Manufacturers > P - S > SSAC > Timers & Flashers > Tower & Obstruction Lighting Controls > FB120A / FB230A Series

FB120A / FB230A Series
Sort By:
1
FB120A - SSAC FB120A - SSAC Beacon Failure Alarm 120VAC for Two 620 or 700W Bulbs

Beacon Failure Alarm 120VAC for Two 620 or 700W Bulbs (SSAC FB120A)

Usually Ships in 3 to 5 Days
Price: $237.74
FB230A - SSAC FB230A - SSAC Beacon Failure Alarm 230VAC for Two 500 or 700W Bulbs

Beacon Failure Alarm 230VAC for Two 500 or 700W Bulbs (SSAC FB230A)

Usually Ships in 3 to 5 Days
Price: $273.41
   
 
1
FB120A / FB230A Series

The FB120A and FB230A are used to monitor the operation of one two-lamp incandescent beacon and one beacon flasher (or auxiliary module). The flasher and lamps are monitored by sensing the flow of current in the circuit. If the lamp(s) or the flasher fail to operate properly, a solid-state output and an isolated SPDT relay energize. When connected to a site monitoring system, this unit provides the remote beacon monitoring protection required by the FAA/FCC. On a multiple beacon structure, one unit is required for each two-lamp incandescent beacon (one unit per beacon for LED beacons).

Operation
If one lamp in an incandescent beacon fails, the relay and solid-state lamp failure outputs energize after 10s. If the flasher fails in the ON or OFF condition, the relay and the solid-state flasher failure output energizes after 6s. If both failures occur, all three outputs energize after their trip delays.

Note: If both incandescent lamps fail, all three outputs will energize. The relay and solid-state flasher failure output energizes after 6s, and the solid-state lamp failure output energizes after 10s.

Features:

  • Senses failed flashing incandescent beacon lamps & beacon flashers
  • Toroidal current sensing
  • One isolated, 5A, SPDT alarm output
  • Two 1A, solid-state line voltage alarm outputs
  • Trip delays prevent nuisance alarms