Walker Industrial: Home > Manufacturers > P - S > SSAC > Timers & Flashers > Voltage Monitors & Phase Monitors > PLM Series

PLM Series
Sort By:
1
PLM6405 - SSAC PLM6405 - SSAC 3 Phase Voltage Monitor 240VAC 4%VUB 5s Trip 8-PIN

3 Phase Voltage Monitor 240VAC 4%VUB 5s Trip 8-PIN (SSAC PLM6405)

Usually Ships in 3 to 5 Days
Price: $126.26
PLM6502 - SSAC PLM6502 - SSAC 3 Phase Voltage Monitor 240VAC 5%VUB 2s Trip 8-PIN

3 Phase Voltage Monitor 240VAC 5%VUB 2s Trip 8-PIN (SSAC PLM6502)

Usually Ships in 3 to 5 Days
Price: $126.26
PLM6805 - SSAC PLM6805 - SSAC 3 Phase Voltage Monitor 240VAC 8%VUB 5s Trip 8-PIN

3 Phase Voltage Monitor 240VAC 8%VUB 5s Trip 8-PIN (SSAC PLM6805)

Usually Ships in 3 to 5 Days
Price: $126.26
PLM8405 - SSAC PLM8405 - SSAC 3 Phase Voltage Monitor 380VAC 4%VUB 5s Trip 8-PIN

3 Phase Voltage Monitor 380VAC 4%VUB 5s Trip 8-PIN (SSAC PLM8405)

Usually Ships in 3 to 5 Days
Price: $126.26
PLM9405 - SSAC PLM9405 - SSAC 3 Phase Voltage Monitor 480VAC 4%VUB 5s Trip 8-PIN

3 Phase Voltage Monitor 480VAC 4%VUB 5s Trip 8-PIN (SSAC PLM9405)

Usually Ships in 3 to 5 Days
Price: $126.26
PLM9502 - SSAC PLM9502 - SSAC 3 Phase Voltage Monitor 480VAC 5%VUB 2s Trip 8-PIN

3 Phase Voltage Monitor 480VAC 5%VUB 2s Trip 8-PIN (SSAC PLM9502)

Usually Ships in 3 to 5 Days
Price: $126.26
PLM9805 - SSAC PLM9805 - SSAC 3 Phase Voltage Monitor 480VAC 8%VUB 5s Trip 8-PIN

3 Phase Voltage Monitor 480VAC 8%VUB 5s Trip 8-PIN (SSAC PLM9805)

Usually Ships in 3 to 5 Days
Price: $126.26
   
 
1
PLM Series

The PLM Series continuously measures the voltage of each of the three phases. The PLM Series uses a microcontroller circuit design that senses undervoltage, voltage unbalance, phase loss, and phase reversal. Protection is assured when regenerated voltages are present. Both delta and wye systems can be monitored; no connection to neutral is required.

Operation:
The output relay is energized and the LED glows green when all voltages are acceptable and the phase sequence is correct. Under and unbalanced voltages must be sensed for a continuous trip delay period before the relay de-energizes. Reset is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied. The LED flashes red during the trip delay, then glows red when the output de-energizes. The LED flashes green/red if phase reversal is sensed.

Field Adjustment:
Set voltage adjustment knob at the desired operating line voltage for the equipment. This adjustment automatically sets the undervoltage trip point. Apply power. If the PLM fails to energize, (LED glows red) check wiring of all 3 phases, voltage, and phase sequence. If phase sequence is incorrect, the LED flashes green/red. To correct this, swap any two line voltage connections at the mounting socket. No further adjustment should be required.

Features:

  • Protects against phase loss & reversal; & under & unbalanced voltages
  • 8-pin plug-in base
  • Adjustable low voltage trip point
  • Factory fixed unbalance & trip delay
  • Line voltages 200 to 480VAC in 3 ranges
  • Isolated, 10A, SPDT output contacts
  • ASME A17.1 rule 210.6
  • NEMA MG1 14:30, 14:35
  • IEEE C62.41-1991 Level B