Walker Industrial: Home > Manufacturers > P - S > SSAC > Timers & Flashers > Current Sensors & Monitors > TCS Series

TCS Series
Sort By:
1
TCSG2A - SSAC TCSG2A - SSAC Current Sensor FXD 2A NO 3 50VDC 2x2

Current Sensor FXD 2A NO 3 50VDC 2x2 (SSAC TCSG2A)

Usually Ships in 3 to 5 Days
Price: $75.82
TCSGAA - SSAC TCSGAA - SSAC Current Sensor Adjustable 2 20A NO 3 50VDC 2x2

Current Sensor Adjustable 2 20A NO 3 50VDC 2x2 (SSAC TCSGAA)

Usually Ships in 3 to 5 Days
Price: $75.82
TCSGAB - SSAC TCSGAB - SSAC Current Sensor Adjustable 2 20A NC 3 50VDC 2x2

Current Sensor Adjustable 2 20A NC 3 50VDC 2x2 (SSAC TCSGAB)

Usually Ships in 3 to 5 Days
Price: $75.82
TCSH2A - SSAC TCSH2A - SSAC Current Sensor FXD 2A NO 24 240VAC 2x2

Current Sensor FXD 2A NO 24 240VAC 2x2 (SSAC TCSH2A)

Usually Ships in 3 to 5 Days
Price: $75.82
TCSH2B - SSAC TCSH2B - SSAC Current Sensor FXD 2A NC 24 240VAC 2x2

Current Sensor FXD 2A NC 24 240VAC 2x2 (SSAC TCSH2B)

Usually Ships in 3 to 5 Days
Price: $75.82
TCSHAA - SSAC TCSHAA - SSAC Current Sensor Adjustable 2 20A NO 24 240VAC 2x2

Current Sensor Adjustable 2 20A NO 24 240VAC 2x2 (SSAC TCSHAA)

Usually Ships in 3 to 5 Days
Price: $75.82
TCSHAB - SSAC TCSHAB - SSAC Current Sensor Adjustable 2 20A NC 24 240VAC 2x2

Current Sensor Adjustable 2 20A NC 24 240VAC 2x2 (SSAC TCSHAB)

Usually Ships in 3 to 5 Days
Price: $75.82
   
 
1
TCS Series

The TCS Series is a low cost method of go/no go current detection. It includes a solid-state output to sink or source current when connected directly to a standard PLC digital input module. Its normally open or normally closed output can also be used to control relays, lamps, valves, and small heaters rated up to 1A steady, 10A inrush. The TCS is self-powered (no external power required to operate the unit) and available with an adjustable actuation range of 2 - 20A or factory fixed actuation points from 2 - 45A.

Operation
Normally Open: When a current equal to or greater than the actuate current is passed through the toroidal sensor, the output closes. When the current is reduced to 95% of the actuate current or less, the output opens. Normally Closed: When the current through the toroid is equal to or greater than the actuate current, the output opens. When the current is reduced below 95% of the actuate current, the output closes. To increase sensitivity, multiple turns may be made through the TCS's toroidal sensor. The trip point range is divided by the number of turns through the toroidal sensor to create a new range. When using an external CT, select a 2VA, 0-20A output CT rated for the current to be monitored. Select TCS adjustment range 0. Pass one secondary wire lead through the TCS' toroid and connect the secondary leads together.

Features:

  • Direct connection to a PLC digital input module
  • 3 to 50VDC, 24 to 240VAC
  • 1A steady - 10A inrush
  • Actuation Points -
    • 2 - 45A (fixed units)
    • 2 - 20A (adjustable units)
  • NO or NC solid-state output
  • Complete isolation between sensed current & control circuit

Auxiliary Products:

  • Female quick connect: P/N: P1015-64 (AWG 14/16)
  • Mounting bracket: P/N: P1023-6
  • Quick connect to screw adaptor: P/N: P1015-18
  • DIN rail: P/N: C103PM (Al)
  • DIN rail adaptor: P/N: P1023-20